Description
Summit Compact Vaccine Medical Freezer Description:
The Accucold® VAC Series freezers are specially designed to store sensitive medical and pharmaceutical materials under the proper conditions, with innovative construction for temperature stability and user-friendly features for added convenience.
The Summit FS24LVAC Compact Vaccine Medical Freezer is a compact all-freezer designed to reach -20º C, the ideal temperature for long-term storage of select sensitive materials. The 1.4 cu.ft. manual defrost interior offers static cooling for stable results. A removable wire shelf allows easy storage options, with a seamless interior liner to simplify cleanup. This unit has a flat door liner as recommended by the CDC.
For optimum temperature assurance, the Summit FS24LVAC Compact Vaccine Medical Freezer includes a digital thermostat and a high/low temperature alarm with a NIST calibrated temperature display to the nearest tenth of a degree. A hospital grade cord includes a ‘green dot’ plug for added safety in high traffic settings, while the self-closing door ensures stored items aren’t accidentally exposed to room temperature. This model comes in a white finish and includes a factory installed lock. An access port with a contact is pre-installed, allowing users to install additional monitoring equipment. Customers can specify the access port location upon order.
The Summit FS24LVAC Compact Vaccine Medical Freezer can be paired with the FFAR24LVAC all-refrigerator for a matching set. These units can also be ordered with more advanced medical features, including a power-out alarm, temperature logger, and more.
Summit Compact Vaccine Medical Freezer Features:
- Compact dimensions– Ideal size for use on top of counters
-20° capable– Low temperature capability ideal for certain sensitive items - Digital thermostat– Electronic controls for more precise temperature management
- High/low temperature alarm– Audible alarm sounds if the interior temperature rises or falls out of set range
- NIST calibrated temperature display– Alarm includes NIST calibrated display of the current interior and high/low temperature to the nearest tenth of a degree
- Factory installed lock– Keyed lock for secure interior
- Self-closing door– Door closes automatically when opened at angles less than 90º
- Access port with contact– Pre-installed probe with contact allows users to install their own monitoring equipment; customers can specify placement of the access port upon order
- Hospital grade cord with ‘green dot’ plug– Secure three-pronged cord for added unit safety
- Manual defrost– Static cooling system for reduced temperature fluctuations
- Removable shelf– Includes one wire shelf for easier storage
- One-piece interior liner– Seamless interior for easier cleanup
- Flat door liner– Interior design conforms to CDC guidelines to ensure stable conditions for sensitive materials
- Factory reversible door– Standard unit ships RHD but can be ordered LHD
- 100% CFC Free– Environmentally friendly design with no ozone-damaging chemicals
Summit Compact Vaccine Medical Freezer Specifications:
- Height of Cabinet– 21.38″
- Width– 18.5″
- Depth– 17.63″
- Depth with door at 90°– 34.5″
- Capacity– 1.4 cu.ft.
- Defrost Type– Manual
- Door– White
- Cabinet– White
- US Electrical Safety– ETL
- Canadian Electrical Safety– ETL-C
- Amps– 0.8
- Voltage/Frequency– 115 V AC/60 Hz
- Weight– 35.0 lbs.
- Shipping Weight– 37.0 lbs.
- Estimated Time to Ship– 5 to 7 days
- Parts & Labor Warranty– 2 Years
- Compressor Warranty– 5 Years
Summit Compact Vaccine Medical Freezer Overview:
- Door Swing– RHD
- Reversible– Factory Reversible
- Interior Height– 14.38″
- Interior Width– 13.5″
- Interior Depth– 13.25″
- Shelf Type– Wire
- Shelf Qty– 1
- Thermostat Type– Dial
- Refrigerant Type– R134a
- Refrigerant Amount– 1.5 oz.
- Level Legs– 2
- Compressor Step Height– 8.5″
- Compressor Step Width– 13.5″
- Compressor Step Depth– 6.0″
Summit Appliance manufactures compact and specialty major appliances: including refrigerators, freezers, laboratory and scientific refrigeration and refrigerated and freezer drawers. Our products are grouped into: laboratory, medical and scientific refrigerators and freezers.
Product FAQ
What is the FS24LVAC and what is it used for?
The FS24LVAC is a 1.4 cu ft (~40 L) compact, countertop-sized freezer purpose-built for vaccine, medication and medical-grade storage applications. It is capable of reaching approximately -20 °C and includes features designed to meet rigid monitoring/storage protocols.
What are the key technical specifications?
• Capacity: 1.4 cu ft (~40 L).
• External dimensions: Height ~54 cm, Width ~47 cm, Depth ~45 cm; door-open depth ~88 cm.
• Temperature range: Down to approximately -20 °C.
• Shelves: 1 removable wire shelf.
• Monitoring/alarms: Digital thermostat, high/low temperature alarm with NIST-calibrated display, factory installed lock, access port for external monitoring.
• Warranty: 2 years parts & labor; 5 years compressor.
What safety and security features are included?
Features include:
– Factory-installed keyed lock for secure access.
– Self-closing door to reduce accidental exposure to room temperature.
– Flat door liner (compliant with CDC/VFC guidelines) and hospital-grade ‘green dot’ plug for high-traffic use.
Which environments is this unit best suited for?
Ideal for medical clinics, laboratories, pharmacy vaccine storage counters and research environments where ultra-low (~-20 °C) temperature storage is required in a small footprint. Not intended for temperatures significantly below -20 °C unless further validated.
Shipping FAQ
How long does shipping take after placing an order?
Typical shipping lead time is 5–7 days when the unit is in stock and ready for dispatch.
Is international shipping available and what should I consider for Melbourne, Australia?
Yes — international shipping is available. For delivery to Melbourne, Australia you should consider:
• Import duties and GST.
• Site access: confirm pathways/doorways/elevator can handle ~47 cm width × ~45 cm depth and allow ~88 cm door-open clearance.
• Electrical compatibility: This U.S. version is rated at 115 V AC / 60 Hz — for Australia (230 V / 50 Hz) you must ensure the correct regional variant or use a certified transformer/adaptor.
How is the unit packaged for transit and what site requirements should be met?
The unit ships palletized/boxed; unpacked footprint ~54 cm H × 47 cm W × 45 cm D; allow sufficient clearance for door-open (~88 cm). Delivery zone must be level, firm and clear from vehicle to installation site.
What should I do if my shipment arrives damaged or is delayed?
On delivery inspect the outer packaging and unit for visible transit damage. If damage is present: photograph condition, retain packaging and delivery receipt, then contact your supplier with order/tracking details to initiate a freight claim or replacement.
Application FAQ
How do I install and set up the FS24LVAC?
1. Place the unit on a firm, level indoor surface (bench or countertop) in a climate-controlled area; allow rear/side clearance for ventilation and ensure ~88 cm linear clearance in front for door opening.
2. Connect to a grounded power outlet matching the ordered variant (115 V/60 Hz U.S. or appropriate local version).
3. Power on the freezer, set the digital control to target temperature (-20 °C) and allow several hours (typically 4–6 h) for interior temperature stabilization before loading sensitive contents.
What best practices should I follow when using this freezer?
• Place contents evenly on the wire shelf, leaving enough clearance for airflow and avoiding over-packing.
• Label stored materials with date/time and maintain a first-in/first-out (FIFO) rotation where possible.
• Minimize door openings; rely on external display and included monitoring probe rather than frequent door access.
• Regularly inspect door gasket/seal, check lock/handle operation, and ensure the interior is kept clean and the unit remains level.
What should I do if a temperature excursion or power interruption occurs?
If the interior temperature rises above or falls below the target (~-20 °C) or if power interruption occurs:
• Record the event: date/time, observed temperature, and impacted contents.
• Transfer critical materials to validated backup cold storage until conditions stabilize.
• Investigate the root cause (door left open, ambient heat load, power/sensor fault).
• After recovery and once temperature has stabilized within target range, inspect stored items for integrity before resuming standard use.
What maintenance and verification routines are recommended?
• Monthly: Inspect door gasket/seal, hinges and lock/handle to ensure secure closure and level operation.
• Quarterly: Clean interior and exterior surfaces; check ventilation/exhaust pathways; verify alarm and NIST-calibrated display is functioning.
• Periodically: Review and export minimum/maximum internal temperature logs (if applicable), ensure calibration certificate is valid and document all service/maintenance actions for compliance.