Description
ABS ABT-HC-LP-47-TS Laboratory Refrigerator Templog Premier
The ABS ABT-HC-LP-47-TS Laboratory Refrigerator Templog Premier are purpose built for scientific and medical applications. Units feature a digital microprocessor temperature controller allowing for the precise temperature management necessary for critical samples and supplies. A forced air directional refrigeration system provides superior temperature uniformity and recovery after door openings. An automatic cycle-defrost design prevents product damaging temperature spikes.
The ABS ABT-HC-LP-47-TS Laboratory Refrigerator Touch Screen temperature display and alarm module offers the latest in advanced temperature control and data logging.
Environmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA/SNAP mandates and UL, ASHRAE compliance guidelines.
Pharmacy Refrigerator Features:
- 47 cu. Ft. Capacity
- Two sliding glass doors, self-closing (energy efficient, double pane vacuum insulated)
- Forced draft air circulation
- Eight adjustable shelves (adjustable in ½” increments)
- Keyed door lock
- Magnetic door gasket for positive seal
- Heavy duty door handle
- Led interior lights are safety shielded and switch controlled
- Swivel casters (3 ½”)
- Probe access port (3/8″)
- White powder-coated steel exterior and interior
- High density urethane foam cabinet insulation
- Hydrocarbon, natural refrigerant (r290)
- Three year parts and labor warranty, plus an additional two year compressor parts warranty
- Etl listed
Pharmacy Refrigerator Specifications:
- Exterior dimensions: 54 1/8” w x 33 1/4 d x 81 3/4” h without casters; 78 1/4” h with casters
- Cycle defrost
- 115v, 60 hz, 4.5 amps, 1/4 hp
- Shipping weight: 508 lbs.
Pharmacy Refrigerator Temp Controller:
- Microprocessor temperature controller
- Adjustable operating temperature range: 1°c – 10°c
- Touch screen digital temperature display and alarm module
- Password-protected control panel
- Sample simulated digital temperature display; .1° resolution, adjustable temperature display in celsius or fahrenheit
- Active temperature scale bar display
- Resettable 1-point min/max history
- Digital 24-hour temperature chart
- Temperature data logging
- Usb port for data transfer and software updates
- Real-time operational display clock
- 4-20ma output
- Electronic troubleshooting guide
- Electronic qr code to access owner’s manual & technical support contact information
- Adjustable alarm volume
- Audible and visual high/low temperature alarms
- 2 probes; 1 in air and 1 in sample bottle
- Sensor error alarm
- Power failure alarm
- Door ajar alarm
- Low battery alarm
- Operation indicator
- Alarm validation (audible, visual, and remote alarm) and alarm mute with ring back remote alarm contacts
ABS have a vast selection of laboratory refrigeration and freezer models to choose from, ranging down to Ultra-Low -86°C cascade freezers and -196°C cryogenic freezers.
Product FAQ
What are the advantages of the TempLog Premier series?
The TempLog Premier series is engineered for high-precision temperature management. It features a sophisticated touchscreen control module with integrated digital data logging, password-protected security, and comprehensive alarm systems, making it ideal for the most sensitive laboratory and pharmacy requirements.
What does the digital data logging feature provide?
The system provides 24-hour continuous temperature chart monitoring, resettable min/max history, and a USB port for easy data transfer and software updates. It also offers real-time operational status, electronic troubleshooting, and a QR code link for instant access to manuals and support.
What temperature management systems are included?
This unit uses a microprocessor-controlled system with forced draft air circulation to ensure superior temperature uniformity throughout the spacious 47 cu. ft. cabinet, as well as an automatic cycle-defrost feature to eliminate temperature spikes during defrosting.
What is the warranty coverage?
It comes with a three-year parts and labor warranty, plus an additional two-year compressor parts warranty to ensure long-term operational reliability.
Shipping FAQ
How is this large-capacity laboratory refrigerator shipped?
Due to its 47 cu. ft. size, weight, and delicate glass-door configuration, this unit is shipped via dedicated LTL (Less-Than-Truckload) freight, secured on a heavy-duty pallet to ensure it arrives in optimal condition.
Do I need liftgate service?
Yes, liftgate service is mandatory unless your facility has a loading dock capable of receiving an 18-wheeler truck, as this unit must be safely lowered from the trailer to the ground level.
What should I inspect upon arrival?
Before signing the delivery receipt, you must thoroughly inspect the unit, focusing specifically on the glass door seals, the exterior finish, and the refrigeration housing for any signs of shipping damage.
What are the post-delivery setup steps?
To prevent damage to the compressor and ensure long-term stability, you must allow the unit to sit upright in its final location for at least 24 hours to let all fluids settle before powering it on.