Description
Summit Vaccine Healthcare Refrigerator Description:
EQTemp by Accucold introduces a new series of NSF/ANSI 456 certified refrigeration designed to store a variety of materials in healthcare facilities.
Summit ACR52GNSF456LHD Vaccine Healthcare Refrigerator is an upright 3.88 cu.ft. all-refrigerator. It features a clean white exterior and a blue-accented control panel. The glass door is equipped with a self-closing mechanism to help protect stored items from being overexposed to room temperature. A factory-installed lock offers added security, and the hospital-grade cord with a ‘green dot’ plug ensures a secure connection for high-traffic areas. This unit features a front-breathing design for safe built-in installation under counters. The fully finished cabinet also allows freestanding use.
The Summit ACR52GNSF456LHD Vaccine Healthcare Refrigerator includes an external readout of the interior temperature, as well as the high/low temperature as required for data records. The buffered temperature probe is encased in a bottle filled with glass beads for improved accuracy and calibrated to NIST standards in our in-house ISO/IEC 17025:2017 certified laboratory. The digital temperature controls allow you to set the interior between 2 and 8ºC. An audible alarm sounds if the temperature goes out of range. We also include a pre-installed 3/8″ access port for users to add their own monitoring equipment if preferred. The interior includes one wire shelf in the center to hold the temperature probe, as well as additional adjustable shelves to accommodate different sizes. Internal LED lighting provides an efficient and convenient view. Automatic defrost reduces user maintenance and an internal fan ensures powerful temperature recovery after door openings. This unit ships with a left-hand door swing (for a right-hand version, see model ACR52GNSF456).
EQTemp’s series of ACR refrigeration is certified to the NSF/ANSI 456 Vaccine Storage Standard. All models feature hydrocarbon refrigerant for a greener footprint. Additional sizes are available, as well as more advanced cold storage equipment purpose-built for laboratory and life science storage. Browse the full product line to explore our extensive selection.
Note: EQTemp’s ACR Series refrigerators are intended for a wide variety of healthcare storage applications. Storage of high-value vaccines, life science materials, and medical/clinical biologicals require a product offering tighter temperature control and/or alarms, monitoring, and backup.
Summit Vaccine Healthcare Refrigerator Features:
- EQTemp Healthcare Refrigerator– All-refrigerator designed to operate between 2 and 8ºC for a variety of storage application in medical offices and other healthcare facilities
- Certified to NSF/ANSI 456 Vaccine Storage Standard– Tested to comply with the latest standards
- Certificate of calibration included– The temperature monitoring device (TMD) is calibrated to NIST standards in our ISO/IEC 17025:2017 certified calibration laboratory and ships with a 2-year certificate of calibration for your records
- Temperature Range: 2º to 8ºC– Preset to 5ºC as recommended for many storage applications
- External temperature readout– Includes continuous display of the current interior and high/low temperature, and can be switched from Celsius to Fahrenheit at the touch of a button
- Digital thermostat– Digital microprocessor for easy and precise temperature management, with all controls externally located for added convenience
- Built-In capable– Front-breathing design lets you make the best use of space by installing your appliance under the counter
- High/low temperature alarm– Audible alarm sounds if the interior temperature rises or falls out of set range
- Buffered temperature probe– Thermometer probe is encased in a glass bead-filled bottle and stored in a fixed box on the center shelf. This is the ideal way to produce temperature readings closest to stored contents, as recommended by the CDC and VFC’s guidelines
- Access port– 3/8″ probe hole with cover is pre-installed in unit’s side to allow easy installation of user-provided monitoring equipment
- Factory installed lock– Keyed lock for a secure interior (2 keys included)
- Automatic defrost– Reduced user maintenance with automatic defrost
- Internal fan– Fan-forced cooling ensures the unit is evenly cooled from top to bottom
- Hospital grade cord with ‘green dot’ plug– Secure three-pronged cord for added unit safety in high traffic areas
- Adjustable wire shelving– Designed to ensure proper air circulation for more even temperature distribution
- Fixed center shelf– Center shelf is fixed in place in order to provide the optimum position for the TMD to provide the most accurate temperature readings
- Flat door liner– No door storage to allow for the interior to accommodate deeper trays
- LED lighting– Attractively illuminates the interior in a gentle white hue for easy viewing
- Foamed-in-place cabinet– Quality design ensures efficiently insulated interior
- Temperature memory function– Unit will retain its last settings when power is restored in the event of power loss
- Self-closing door– Door will automatically close when left ajar, preventing items from accidentally being left exposed to ambient temperatures
- Pocket handle– Handle is recessed into the side of the door to ensure no added depth
- Open door alarm– Audible alarm sounds if the door is left open for more than one minute
- Digital thermostat– Digital microprocessor for easy and precise temperature management, with all controls externally located for added convenience
- Magnetic door gasket– Quality door gaskets ensure a tight seal for energy savings and improved performance
- Fully finished white cabinet– Allows the unit to be used freestanding
- Left hand door swing– For this unit with a standard right hand door swing, see model ACR52GNSF456
- CARB Compliant– Eco-friendly hydrocarbon-based refrigerant for a greener footprint that meets current CARB regulations
- 100% CFC free– Environmentally friendly design without ozone-damaging chemicals
Summit Vaccine Healthcare Refrigerator Specifications:
- Height of Cabinet– 34.0″
- Width– 23.5″
- Width with Door Open– 23.75″
- Depth– 21.75″
- Depth with door at 90°– 43.75″
- Capacity– 3.88 cu.ft.
- Defrost Type– Automatic
- Door– Glass
- Cabinet– White
- US Electrical Safety– ETL
- Canadian Electrical Safety– ETL-C
- Sanitation– ETL-S to NSF 456
- Amps– 2.0
- Voltage/Frequency– 115 V AC/60 Hz
- Weight– 91.5 lbs.
- Shipping Weight– 120.0 lbs.
- Parts & Labor Warranty– 1 Year
- Compressor Warranty– 5 Years
Summit Vaccine Healthcare Refrigerator Features:
- Door Swing– LHD
- Reversible– Factory Reversible
- Shelf Type– Wire
- Shelf Qty– 3
- Adjustable Shelves– Yes
- Thermostat Type– Digital
- Fan Type– Interior
- Refrigerant Type– R600a
- Refrigerant Amount– 1.23oz.
- High Side PSI– 1.45
- Low Side PSI– 0.85
- Level Legs Qty– 2
- Interior Light– Yes
- Temperature Range– 2º to 8ºC
Summit Vaccine Healthcare Refrigerator Dimensions:
- Interior Height– 28.88″
- Interior Width– 18.75″
- Interior Depth– 16.5″
- Compressor Step Height– 4.0″
- Compressor Step Width– 18.75″
- Compressor Step Depth– 11.5″
Summit Appliance manufactures compact and specialty major appliances: including refrigerators, freezers, laboratory and scientific refrigeration and refrigerated and freezer drawers. Our products are grouped into: laboratory, medical and scientific refrigerators and freezers.
Product FAQ
What is the ACR52GNSF456LHD and what is it used for?
The ACR52GNSF456LHD is a built-in 24″-wide medical/healthcare refrigerator with approximately 3.88 cu ft (≈ 110 L) capacity, designed for vaccine, medication, or clinical storage in healthcare facilities where strict temperature control and monitoring are required.
What temperature range and control features does it support?
It supports an operating range of approximately +2 °C to +8 °C (+35 °F to +46 °F). It features a digital microprocessor thermostat, external temperature readout, and a buffered probe for product-accurate monitoring.
What alarm and monitoring features are included?
Includes audible/visual high/low temperature alarms, door-ajar alarm, power-failure alert, internal fans for even cooling, remote alarm contact outputs, and a probe access port for external monitoring equipment.
What construction and usability features support its purpose?
Features include a self-closing glass door, factory-installed keyed lock, hospital-grade “green-dot” plug, front-breathing design for built-in placement, sealed back cabinet suitable for freestanding use, adjustable wire shelving, LED interior lighting, and calibrated temperature monitoring.
What environments and applications is this unit best suited for?
Ideal for vaccine storage rooms, clinical pharmacy areas, patient-care settings, immunization services or other healthcare environments that require reliable +2 °C to +8 °C cold storage in a space-efficient footprint.
Shipping FAQ
What are the exterior dimensions and shipping weight?
Cabinet dimensions approximately 34.0″ H × 23.5″ W × 21.75″ D (≈ 86 cm × 60 cm × 55 cm); shipping weight around 91.5 lbs (≈ 42 kg).
What power and installation requirements apply?
Operates on 115 V AC / 60 Hz, draws around 2.0 amps; requires a dedicated grounded outlet, level installation, and adequate ventilation especially for built-in configurations.
What unpacking or installation considerations should I know?
Inspect the unit on delivery for damage, allow upright settling if transported on its side, verify correct door swing and placement, ensure back and side clearance for ventilation, and test temperature controls and alarms before loading contents.
What shipping or delivery method is typical for this unit?
Given its size and specification, delivery is often by standard pallet freight. Confirm receiving area clearance, ensure safe off-loading, and plan for front-breathing ventilation in built-in installations.
Application FAQ
Is this unit suitable for vaccine or pharmaceutical cold-chain storage?
Yes — the ACR52GNSF456LHD is certified to the NSF/ANSI 456 vaccine-storage standard, making it suitable for health-care facility use where +2 °C to +8 °C is required and compliance with vaccine-handling protocols is mandated.
What best practices should be followed for daily operation?
Install a calibrated data-logger or min/max thermometer at shelf-mid level, label and rotate stored contents, avoid over-packing that restricts airflow, minimise door-open time, record start-of-day internal temperature, and review high/low logs regularly.
What maintenance routine is recommended?
Check the door-gasket seal for tight closure annually, clean condenser/vent pathways semi-annually, test alarm and control functions monthly, ensure the unit remains level and free of obstruction, and verify probe calibration periodically.
What should I do in the event of a temperature excursion or alarm?
Document date/time of the alarm, measured temperature deviation and affected contents; transfer items to alternative storage if required; inspect causes (door left open, airflow blockage, power issue); return unit to set-point and log corrective actions as per facility SOP.