Description
Summit Undercounter Medical Freezer Description:
Accucold by Summit Appliance’s MED series all-freezers come fully featured for stabilized temperature performance for use in medical, scientific, pharmaceutical, and laboratory institutions.
The Summit VT65MLMED Undercounter Medical Freezer has a 24″ footprint designed for freestanding use. It comes in a white finish and includes a front-mounted lock for added security.
The manual defrost Summit VT65MLMED Undercounter Medical Freezer operates several degrees colder than most freezers for safe long-term storage of food, vaccines, or pharmaceuticals. Temperatures can reach and maintain -25º C. Three removable pull-out basket drawers provide convenient storage solutions, while extra thick insulation limits energy waste and keeps the cold inside.
We include an audible NIST calibrated temperature alarm complete with an external display of the current and high/low temperature mounted on the door. A green dot hospital grade plug is installed for added safety in high traffic areas. An access port allows users to connect their own monitoring equipment.
With its slim size and reliable construction, the VT65MLMED works well in any setting in need trusted storage. For a built-in version of this model, see the VT65MLBIMED. Additionally, we offer a variety of options to customize this unit, including USB data loggers, digital thermostats, self-closing doors, and more.
NOTE: Accucold freezers are purpose-built to the support meeting the current CDC (Centers for Disease Control) guidelines for the storage of vaccines. As referenced in the current Vaccine Storage and Handling Toolkit, these units incorporate several key features for stable operation. For additional temperature assurance, the CDC recommends a calibrated digital data logger (DDL), which can be added with the factory-installed option DL2B or addition of the DL2BKit accessory. Select Accucold products have been tested and certified to the new NSF 456 standard, and are now available for purchase. For additional information, contact our products specialists.
Summit Undercounter Medical Freezer Features:
- -25ºC capable– Low temperature capability ideal for certain sensitive items
- Factory installed lock–Keyed lock for secure interior
- High temperature alarm–Warns of temperature fluctuations and includes an external temperature readout on the door
- Hospital grade cord with ‘green dot’ plug–Secure three-pronged cord for added unit safety
- Manual defrost–Efficient performance with reliable temperature stability
- Pull-out drawers–Clear baskets for convenient and separated storage
- Access port– Unit comes with a factory installed probe hole for users to connect their own monitoring equipment
- Adjustable thermostat–Manage the temperature with ease and accuracy
- Fully finished white cabinet– Allows the unit to be used freestanding
- 100% CFC Free–Environmentally friendly design with no ozone-damaging chemicals
Summit Undercounter Medical Freezer Specifications:
- Height of Cabinet– 33.5″
- Width– 23.63″
- Depth– 23.5″
- Depth with Handle– 25.13″
- Depth with door at 90°– 46.13″
- Capacity– 3.2 cu.ft.
- Defrost Type– Manual
- Door– White
- Cabinet– White
- US Electrical Safety– UL
- Canadian Electrical Safety– ULC
- Amps– 1.3
- Shipping Weight– 105.0 lbs.
- Shipping Weight– 120.0 lbs. (46 kg)
- Parts & Labor Warranty– 1 Year
- Compressor Warranty– 5 Years
Summit Undercounter Medical Freezer Features:
- Door Swing– RHD
- Reversible– Factory Reversible
- Interior Height– 24.25″
- Interior Width– 17.75″
- Interior Depth– 16.5″
- Thermostat Type– Dial
- Refrigerant Type– R134a
- Refrigerant Amount– 2.7 oz.
- High Side PSI– 235.0
- Low Side PSI– 70.0
- Level Legs– 2
- Interior Drawers– Yes
- Drawers Qty– 3
- Compressor Step Height– 6.5″
- Compressor Step Width– 17.5″
- Compressor Step Depth– 5.5″
- Temperature Range– -12ºC to -25ºC
Summit Appliance manufactures compact and specialty major appliances: including refrigerators, freezers, laboratory and scientific refrigeration and refrigerated and freezer drawers. Our products are grouped into: laboratory, medical and scientific refrigerators and freezers.
Product FAQ
What is the VT65MLMED and what is it used for?
The VT65MLMED is a 3.2 cu ft (~91 L) under-counter medical-grade all-freezer designed for low-temperature storage of sensitive materials in clinical and laboratory environments. It supports temperatures down to approximately –25 °C for applications such as vaccine or pharmaceutical storage.
What are the key technical specifications?
• Capacity: 3.2 cu ft (~91 L)
• External dimensions: Height ~85 cm, Width ~60 cm, Depth ~60 cm; door-open depth ~117 cm
• Temperature range: approx. –12 °C to –25 °C
• Defrost type: Manual
• Interior: Three clear pull-out drawers for organized low-temperature storage
• Security/monitoring: Factory-installed keyed lock, high/low temperature alarm display, access port for external monitoring
• Electrical: 115 V AC / 60 Hz; approx. 1.3 amps
What safety and security features are included?
Features include:
– Keyed door lock for secure access
– Audible temperature alarm for excursions outside the acceptable range
– Factory-installed probe access port for monitoring equipment
– Thick insulated cabinet and magnetic door gasket for superior cold retention
Which environments is this unit best suited for?
Suited for laboratories, medical storage rooms, pharmacies or clinics requiring compact under-counter freezer capacity around –25 °C. Not intended for ultra-low (≤ –80 °C) storage unless separately validated.
Shipping FAQ
How long does shipping take after placing an order?
Typical lead time is approximately 3–5 business days when the unit is in stock.
Is international shipping available and what should I consider for Melbourne, Australia?
Yes — international shipping is available. For delivery to Melbourne, Australia:
• Import duties, customs clearance and GST apply
• Ensure site access: doorways or freight elevators can accommodate approx. 60 cm width × 60 cm depth and allow front clearance of ~117 cm for full door swing
• Electrical compatibility: The standard model is rated for 115 V AC / 60 Hz — for Australia (230 V / 50 Hz) order the correct export variant or use a certified step-down transformer installed by a licensed electrician
How is the unit packaged for transit and what site requirements should be met?
The unit ships boxed and palletized; unpacked footprint approx. 85 cm H × 60 cm W × 60 cm D; door-open depth approx. 117 cm. Delivery path must be level, firm and clear of obstructions from vehicle to installation location.
What should I do if my shipment arrives damaged or delayed?
On delivery inspect the packaging and unit for visible damage. Photograph any damage, retain the packaging and delivery receipt, and contact your supplier with your order/tracking details to initiate a freight claim or arrange replacement.
Application FAQ
How do I install and set up the VT65MLMED?
1. Position the unit on a firm, level indoor surface or under-counter space in a climate-controlled room; allow adequate clearance behind/top and approx. 117 cm front for full door swing.
2. Connect the unit to a dedicated grounded outlet matching the variant’s voltage.
3. Power on the unit, set the digital thermostat to the target of around –25 °C, and allow approximately 4–6 hours for internal temperature stabilization before loading sensitive contents.
What best practices should I follow when using this freezer?
• Arrange stored items with appropriate spacing in the pull-out drawers for proper airflow; avoid over-packing.
• Label items with batch number and date/time; apply first-in, first-out rotation when applicable.
• Minimize door-open events to maintain stable internal chilling.
• Regularly inspect door gasket/seal, hinges/lock mechanism, and ensure the unit remains level and the interior is clean.
What should I do if a temperature excursion or power interruption occurs?
If internal temperature rises above or falls below the target range or a power interruption occurs:
• Record date/time, observed temperature deviation and any impacted contents.
• Transfer critical items to validated backup freezer storage until stable conditions are restored.
• Investigate root cause (door left open, ambient load spike, power/sensor fault).
• Once internal conditions stabilize within acceptable range, inspect stored items for integrity before returning to standard use.
What maintenance and verification routines are recommended?
• Monthly: Inspect door gasket/seal, hinges, and lock; confirm unit remains level.
• Quarterly: Clean interior and exterior surfaces; verify alarm/monitor functions.
• Periodically: Review any temperature logs (if monitoring in use), confirm calibration of monitoring equipment, and maintain documented service/maintenance records for audit-compliance.