Description
Summit Compact Nutritional Commercial Freezer Description:
Accucold’s Nutrition Center Series features commercially approved refrigerators and freezers specifically designed for the storage of sealed food and beverages in a variety of facilities, including break rooms, waiting areas, nurses’ stations, and more.
The Summit FS30L7NZ Compact Nutritional Commercial Freezer is a compact all-freezer sized for countertop use. It is ETL-S listed to NSF-7 standards for the storage of sealed food and beverages. The top cabinet includes a factory installed digital thermometer that provides a continuous external display of the current and minimum/maximum temperature to the nearest tenth of a degree, making it easier for staff to monitor and record the temperature as needed. This device includes a built-in audible alarm that will sound if the unit rises or falls out of the set temperature range. The temperature probe is encased in a glycol-filled bottle to best simulate the temperature of stored contents. All temperature display devices are calibrated to NIST standards in our ISO/IEC 17025:2005 laboratory and include a certificate of calibration.
Inside, the Summit FS30L7NZ Compact Nutritional Commercial Freezer utilizes manual defrost operation. It includes adjustable wire shelves for flexible storage, with a flat door liner to maximize interior depth. The dial thermostat is located inside. A one-piece interior liner ensures easier cleanup.
The Summit FS30L7NZ Compact Nutritional Commercial Freezer comes in a white exterior finish. The user-reversible door includes a front lock for added security. This unit includes a hospital grade cord with a ‘green dot’ plug that stays more securely in wall sockets, a key feature in busy institutional settings.
Designed specifically for institutional food and beverage storage, all Accucold’s Nutrition Centers are commercially approved to NSF standards and comply with most JCAHO recommendations for safe storage. Additional sizes and variations are available.
Summit Compact Nutritional Commercial Freezer Features:
- Commercially approved– ETL-S listed to NSF-7 commercial standards\
- NIST calibrated temperature display– Thermometer provides continuous display of the current and high/low temperature to the nearest tenth of a degree, with a readout switchable from Celsius to Fahrenheit at the touch of a button
- High/low temperature alarm– Audible alarm sounds if the interior temperature rises or falls out of set range
- Compact dimensions– Sized for easy use on top of counters
- Versatile display– Temperature display can be switched from Celsius to Fahrenheit at the touch of a button
- Manual defrost– Static cooling system for improved temperature stability
- Adjustable thermostat– Dial thermostat located inside the unit
- Factory installed lock– Keyed lock for a secure interior
- Reversible door– User-reversible door swing allows for more flexibility in placing the unit
- Removable shelves– Wire shelves can be removed to accommodate different sizes or for easy cleanup
- Flat door liner– Interior design conforms to CDC guidelines to ensure stable conditions for sensitive materials
- One piece interior liner– Easy clean-up with a seamless liner that won’t hold a mess in hidden crevices
- Foamed-in-place cabinet– Designed to ensure a sufficiently insulated interior
- Magnetic door gasket– Quality door gaskets ensure a tight seal for energy savings and improved performance
- Fully finished cabinet– Allows the unit to be used freestanding
- 100% CFC free– Environmentally friendly design without ozone-damaging chemicals
Summit Compact Nutritional Commercial Freezer Specifications:
- Height of Cabinet– 27.0″
- Height to Hinge Cap– 24.63″
- Width– 18.5″
- Depth– 17.75″
- Depth with door at 90°– 34.5″
- Capacity– 1.8 cu.ft.
- Defrost Type– Manual
- Door– White
- Cabinet– White
- US Electrical Safety– ETL
- Canadian Electrical Safety– ETL-C
- Sanitation– ETL-S
- Amps– 0.8
- Voltage/Frequency– 115 V AC/60 Hz
- Weight– 43.0 lbs.
- Shipping Weight– 53.0 lbs.
- Parts & Labor Warranty– 1 Year
- Compressor Warranty– 5 Years
Summit Compact Nutritional Commercial Freezer Features:
- Door Swing– RHD
- Reversible– Yes
- Interior Height– 18.63″
- Interior Width– 13.38″
- Interior Depth– 13.0″
- Shelf Type– Wire
- Shelf Qty– 2
- Thermostat Type– Dial
- Refrigerant Type– R600a
- Refrigerant Amount– 0.8 oz.
- Level Legs– 2
- Compressor Step Height– 8.0″
- Compressor Step Width– 13.38″
- Compressor Step Depth– 5.75″
Summit Appliance manufactures compact and specialty major appliances: including refrigerators, freezers, laboratory and scientific refrigeration and refrigerated and freezer drawers. Our products are grouped into: laboratory, medical and scientific refrigerators and freezers.
Product FAQ
What is the FS30L7NZ and what is it used for?
The FS30L7NZ is a 1.8 cu ft (~51 L) compact all-freezer designed for commercial, medical, and nutritional applications. It is built for countertop or undercounter use and maintains stable temperatures as low as approximately –20 °C, ideal for storing nutritional supplements, samples, or frozen products in professional environments.
What are the key technical specifications?
• Capacity: 1.8 cu ft (~51 L).
• External dimensions: ~52 cm H × 47 cm W × 51 cm D; door-open depth ~93 cm.
• Temperature range: approximately –20 °C to –15 °C (–4 °F to +5 °F).
• Defrost type: Manual.
• Door: Solid white door with factory-installed keyed lock.
• Shelving: 2 removable wire shelves.
• Thermometer: External NIST-calibrated digital display with high/low temperature readout and audible alarm.
• Power: 115 V AC / 60 Hz (U.S. version).
• Certification: ETL-S listed to NSF-7 commercial standards.
• Warranty: 1-year parts & labor; 5-year compressor.
What safety and security features are included?
Features include:
– Factory-installed lock for restricted access.
– Audible alarm and digital thermometer for monitoring temperature excursions.
– Fully finished cabinet for freestanding or built-in use.
– Manual defrost for consistent temperature control with no fan drying.
Which environments is this unit best suited for?
Ideal for nutrition labs, break rooms, pharmacies, and small clinics needing compact, dependable freezer storage of sealed materials or food products. Not designed for vaccine or ultra-low (≤ –40 °C) cold storage unless validated separately.
Shipping FAQ
How long does shipping take after placing an order?
Typical lead time is 5–7 business days when the unit is in stock, plus carrier transit time.
Is international shipping available and what should I consider for Melbourne, Australia?
Yes — international shipping is available. For Melbourne delivery, consider:
• Import duties, customs clearance, and GST.
• Site access: ensure passageways can accommodate ~47 cm width × ~51 cm depth, and provide ~93 cm clearance for full door swing.
• Electrical compatibility: The U.S. model is 115 V / 60 Hz; for Australia (230 V / 50 Hz), order the export variant or use a certified step-down transformer installed by a licensed electrician.
How is the unit packaged for transit and what site requirements should be met?
The unit ships boxed and palletized. Unpacked footprint: ~52 cm H × ~47 cm W × ~51 cm D; door-open depth ~93 cm. Ensure a level and clear pathway from truck to installation site.
What should I do if my shipment arrives damaged or delayed?
Upon delivery, inspect the packaging and unit for visible damage. Photograph any issues, retain all packaging materials, and contact your supplier with order/tracking details to initiate a freight claim or arrange replacement.
Application FAQ
How do I install and set up the FS30L7NZ?
1. Place the freezer upright on a firm, level indoor surface in a climate-controlled environment.
2. Allow space for ventilation around the sides and rear; provide ~93 cm clearance in front for door opening.
3. Connect to a grounded electrical outlet that matches your model’s voltage.
4. Power on and allow 2–4 hours for the temperature to stabilize near –20 °C before loading items.
What best practices should I follow when using this freezer?
• Arrange contents on wire shelves for even airflow; avoid over-packing or blocking vents.
• Use the digital thermometer to monitor conditions instead of frequent door openings.
• Clean the interior periodically and remove frost as needed for optimal performance.
• Keep the door gasket clean and check lock operation regularly.
What should I do if a temperature excursion or power interruption occurs?
• Record the date/time, observed temperature, and affected contents.
• Move critical materials to a backup freezer if needed until normal operation resumes.
• Identify the cause (door ajar, high ambient temperature, power outage).
• Once stable, verify that contents remain intact before resuming normal use.
What maintenance and verification routines are recommended?
• Monthly: Inspect door seal, hinges, and lock; ensure the unit remains level.
• Quarterly: Clean the interior/exterior and verify thermometer accuracy.
• Periodically: Record temperature readings, check calibration, and maintain maintenance records if used in regulated environments.