Description
Summit Countertop MOMCUBE Breast Milk Freezer Description:
Accucold’s MOMCUBE® freezers are designed and purpose-built for breast milk storage. All MOMCUBE® units are laboratory-tested to maintain proper breast milk temperature, as recommended by the CDC and ideal for maternity wards, hospitals, NICUs, employee wellness rooms complying with Section 4207 of the Patient Protection and Affordable Care Act, and other facilities.
The Summit AFZ1PVMCLHD Countertop MOMCUBE Breast Milk Freezer is a 1.4 cu.ft. all-freezer with a temperature range of -18°F to -4°F as recommended for the long-term storage of human milk. The microprocessor temperature controller is externally located to minimize door openings, helping to protect stored contents from ambient temperature. The buffered temperature probe is encased in a glycol-filled bottle to better simulate temperature of the stored milk product, with an additional sensor that reads air temperature to ensure superior temperature control. The current and min/max temperature display is viewable in Celsius or Fahrenheit to the nearest tenth of a degree. The audible and visual temperature alarm sounds if the unit’s interior goes out of range. Additional alarms include a power failure alert, door open alarm, and sensor failure alarm. This model is equipped with remote alarm contacts in the rear and a 1/2″ probe port on the right side to accept additional monitoring devices. A hospital grade cord with ‘green dot’ plug is also included for added safety in high traffic areas.
Inside, this freezer features adjustable plastic-coated wire shelves that can be positioned at 1/2″ increments to accommodate virtually any sized item. This unit includes LED internal lighting with an on/off rocker switch. The interior is constructed from white powder coated metal to ensure added durability and better temperature retention. Static manual defrost cooling helps to ensure stable temperature conditions.
The Summit AFZ1PVMCLHD Countertop MOMCUBE Breast Milk Freezer comes in a white cabinet finish with a blue accented control panel. The factory-installed antimicrobial handle is powder-coated with naturally occurring silver ions, which help to reduce the spread of germs, allowing for a safer, cleaner user experience. The door ships with a left hand swing and self-closing function, while a factory-installed lock provides security as needed, with two keys for staff use. Powerful magnetic gaskets ensure a positive seal.
Designed with hydrocarbon refrigerant, all Accucold Performance Series MOMCUBE freezers provide an energy efficient solution to breast milk storage. Additional sizes, as well as matching refrigerators, are also available.
Summit Countertop MOMCUBE Breast Milk Freezer Features:
- MOMCUBE Breast Milk Freezer– Purpose-built Performance Series freezer for the long-term storage of breast milk
- Purpose-built design– Designed and purpose-built for breast milk storage in accordance with the CDC’s guidelines
- +/-1ºC Variation– The published temperature variation is derived from the maximum deviation of an NTC sensor in a 1 oz. vial located nearest the chamber geometric center during a 24 hour test period
- Adjustable temperature– Intuitive controls let you adjust the interior temperature between -18°F to -4ºF
- Temperature alarm– Visual and audible alarms alert if the interior temperature rises or falls out of set range
- Remote alarm contacts– Electronic controller is equipped with a volt-free contact for alarm forwarding to an external remote system (contacts located in the external rear of the unit)
- Manual defrost operation– Static cooling system for an efficient and stable interior
- Access port– Includes a pre-installed 1/2″ probe hole in the right interior wall to allow easier connection to user-provided monitoring equipment
- Open door alarm– Alarm will sound if the door is left ajar for over 4 minutes (adjustable from 1-99 minutes)
- Audible power failure alarm– Battery-powered alarm sounds if the power connection is interrupted
- Sensor failure alarm– Audible and visual alarm warns if the sensor is disrupted
- Password protection– Control panel requires password entry to adjust the parameters beyond the set point
- Microprocessor control panel– Digital controls with a large LED readout in Celsius or Fahrenheit for intuitive temperature management
- Resettable min/max display– Control panel provides a readout of the low and high temperatures in 15 minute increments
- Factory-installed lock– Keyed lock conveniently located towards the top of the door for added security (2 keys included)
- Antimicrobial silver ion-coated handle– Powder-coated handle with naturally occurring silver ions to help reduce the spread of germs
- Adjustable plastic-coated wire shelves for improved circulation– Shelves can be positioned with a front lip for small storage items or reversed to a flat position to better hold larger items, with multiple shelf positions spaced at 1/2″ to accommodate virtually any size
- Hospital grade cord with ‘green dot’ plug– Secure three-pronged cord for added unit safety
- Durable interior– Walls are constructed from white powder coated metal for added strength and improved temperature retention
- Interior light– Energy efficient LED lighting with internal on/off switch
- Self-closing door– Added protection in busy settings
- Reversible door– User-reversible door swing for added flexibility
- Magnetic door gasket– Quality door gaskets ensure a tight seal for energy savings and improved performance
- Fully finished white cabinet– Allows the unit to be used freestanding
- Extended warranty– 2 years parts and labor/5 years compressor
- Eco-Friendly– Using environmentally friendly hydrocarbons refrigerants for a greener footprint
- Usage stickers– Ships with removable warning stickers for “DO NOT UNPLUG,” “DO NOT ADJUST
- TEMPERATURE,” and “DO NOT STORE PERSONAL ITEMS”, as well as breast milk storage guidelines
- Matching refrigerator– Pair with Accucold ARS2PV (solid door) or ARG2PV (glass door) as a stackable or side-by-side set
- 100% CFC free– Environmentally friendly design without ozone-damaging chemicals
- CARB Compliant– Eco-friendly hydrocarbon-based refrigerant for a greener footprint that meets current CARB regulations
Summit Countertop MOMCUBE Breast Milk Freezer Overview:
- Height of Cabinet– 22.25″
- Width– 18.5″
- Depth with Door Open– 18.88″
- Depth– 23.25″
- Depth with Handle– 24.75″
- Depth with door at 90°– 42.5″
- Capacity– 1.4 cu.ft.
- Defrost Type– Manual
- Door– White
- Cabinet– White
- US Electrical Safety– ETL
- Canadian Electrical Safety– ETL-C
- Amps– 1.3
- Voltage/Frequency– 115 V AC/60 Hz
- Weight– 73.0 lbs.
- Parts & Labor Warranty– 2 Years
- Compressor Warranty– 5 Years
Summit Countertop MOMCUBE Breast Milk Freezer Specifications:
- Door Swing– LHD
- Reversible– Yes
- Interior Height– 6.5″
- Interior Width– 15.25″
- Interior Depth– 15.75″
- Shelf Type– Wire
- Shelf Qty– 2
- Adjustable Shelves– Yes
- Thermostat Type– Digital
- Interior Light– Yes
- Refrigerant Type– R290a
- Refrigerant Amount– 0.85 oz.
- High Side PSI– 280.0
- Low Side PSI– 130.0
- Compressor Step Height– 8.25″
- Compressor Step Width– 15.25″
- Compressor Step Depth– 4.25″
- Temperature Range– -18 to -4ºF
Summit Appliance manufactures compact and specialty major appliances: including refrigerators, freezers, laboratory and scientific refrigeration and refrigerated and freezer drawers. Our products are grouped into: laboratory, medical and scientific refrigerators and freezers.
Product FAQ
What is the AFZ1PVMCLHD and what is it designed for?
The AFZ1PVMCLHD is a compact all-freezer with approximately 1.4 cu ft (≈ 40 L) capacity, designed specifically for secure, long-term breast-milk storage in maternity wards, NICUs, employee lactation rooms or wellness spaces.
What temperature range and control features does it support?
It maintains a temperature range of approximately –18 °C to –4 °C (≈ –0.4 °F to 24.8 °F), using a digital microprocessor controller with a buffered probe to more accurately monitor the stored product’s temperature rather than just air.
What alarm and monitoring features are included?
The unit includes audible/visual high/low temperature alarms, a door-ajar alert, power-failure alarm, sensor-fault alarm, a ½″ probe access port for external monitoring, and remote alarm contacts for facility-wide integration.
What construction and storage features support its purpose?
It features adjustable wire shelving that can be repositioned in fine increments for optimum airflow, an antimicrobial silver-ion coated handle, factory-installed keyed lock, self-closing door, and a sealed back cabinet design for easy placement and cleaning.
Shipping FAQ
What are the unit’s external dimensions and shipping weight?
Height is about 22.25″ (≈ 57 cm), width about 18.5″ (≈ 47 cm), depth about 23.25″ (≈ 59 cm); shipping weight is around 73 lbs (≈ 33 kg).
What are the electrical and installation requirements?
Operates on 115 V AC / 60 Hz with a current draw of ~1.3 amps; requires use of a dedicated grounded outlet and level installation with sufficient ventilation.
Are there any unpacking or placement considerations?
Inspect delivery packaging for damage, allow the freezer to sit upright if transported on its side, level the unit before loading milk, maintain clearances around the rear/side vents, and verify alarm and temperature control functionality prior to loading.
What shipping or delivery method is typical?
Given its size and weight, shipping may be by standard freight or parcel depending on destination. Ensure receiving area accommodates safe delivery, positioning and testing before loading contents.
Application FAQ
Is this freezer suitable for breast-milk storage in clinical or wellness environments?
Yes — it is purpose-built for breast-milk storage, with the correct temperature range, monitoring features and build suitable for maternity, NICU, lactation or employee-wellness applications.
What best practices should be followed for daily operation?
Use a calibrated data logger or min/max thermometer on a shelf at mid-height, label and rotate milk stock regularly, avoid over-packing shelves to maintain proper airflow, minimize door-open duration, and record start-of-day internal temperatures.
What maintenance should be performed regularly?
Check the door-gasket seal annually, clean or vacuum condenser/vent areas at least twice per year, verify the alarm and probe functions monthly or per your protocol, and keep storage area level and unobstructed for reliable performance.
What should you do if a temperature excursion or alarm occurs?
Document the event (time, deviation and contents affected), relocate milk to backup storage if required, identify root cause (such as door left open, airflow blocked or power loss), restore proper conditions, and log the incident as per your facility’s procedure.