Description
Summit Medical Refrigerator Freezer Description:
Accucold offers innovative solutions to vaccine storage with our Performance Series stackable purpose-built refrigerator-freezer combinations designed to support meeting CDC/VFC guidelines.
Sized just under 20″ wide, the Summit ARS8PV-AFZ1PVSTACK Medical Refrigerator Freezer combines the 8 cu.ft. ARS8PV auto defrost all-refrigerator with the 1.4 cu.ft. AFZ1PV all-freezer into one slim footprint using Accucold’s StackRack. This ships in three boxes and requires some minor assembly upon delivery.
The Pharma-Vac Performance Series is designed to meet the demanding needs of vaccine storage. Both units utilize a microprocessor temperature controller (refrigerator range: +2 to +8ºC; freezer range: -30 to -10ºC). The buffered temperature probe is encased in a glycol-filled bottle to better simulate temperature of the stored product, with an additional sensor that reads air temperature to ensure superior temperature control. The current and min/max temperature display is viewable in Celsius or Fahrenheit to the nearest tenth of a degree. The audible and visual temperature alarms sound if the units’ interiors go out of range. Additional alarms include a power failure alert, door open alarm, and sensor failure alarm. Both units are equipped with remote alarm contacts in the rear and a 1/2″ probe port on the right side to accept additional monitoring devices. The factory-installed antimicrobial handles are powder-coated with naturally occurring silver ions, which help to reduce the spread of germs, allowing for a safer, cleaner user experience. A hospital grade cord with ‘green dot’ plug is also included for added safety in high traffic areas.
Inside, the ARS8PV refrigerator utilizes adjustable cycle defrost operation to avoid temperature spikes. Optimized forced air cooling with an internal fan ensures excellent temperature stability and uniformity with rapid recovery after door openings. The adjustable plastic-coated wire shelves can be positioned at 1/2″ increments to accommodate virtually any sized item. This unit includes LED internal lighting with an on/off rocker switch. The interior is constructed from white powder coated metal to ensure added durability and better temperature retention.
Freezer model AFZ1PV can be installed on top of the refrigerator with our stacking rack. This freezer utilizes static manual defrost operation. It comes with two adjustable shelves.
Both units include front-mounted keyed locks and powerful magnetic gaskets to ensure a positive seal, with self-closing doors for added protection in high traffic settings.
NOTE: Accucold refrigerators are purpose-built to the support meeting the current CDC (Centers for Disease Control) guidelines for the storage of vaccines. As referenced in the current Vaccine Storage and Handling Toolkit, these units incorporate microprocessor controls and forced air circulation for stable operation between 2 and 8ºC. For additional temperature assurance, the CDC recommends a calibrated digital data logger (DDL), which can be added with the factory-installed option DL2B or addition of the DL2BKit accessory.
Summit Medical Refrigerator Freezer Features:
- Performance Series Refrigerator-Freezer Combination– Purpose-built all-refrigerator and all-freezer for vaccine storage in medical, pharmaceutical, and life science applications
- Purpose-built design– Designed and purpose-built for pharmacy, medication, and vaccine applications to support meeting CDC/VFC guidelines
- +/-1ºC Variation– The published temperature variation is derived from the maximum deviation of an NTC sensor in a 1 oz. vial located nearest the chamber geometric center during a 24 hour test period
- Space-saving design– Allows you to create a full refrigerator-freezer with independent controls in a slim-fitting footprint
- Easy assembly– Unit ships in three boxes for customer to install the StackRack on the bottom refrigerator/freezer and place and secure the other unit on top
- Antimicrobial silver ion-coated handles– Powder-coated handles with naturally occurring silver ions to help reduce the spread of germs
- Adjustable temperature– Intuitive controls let you adjust the interior temperature between +2 to +8ºC (refrigerator) and -30º to -10ºC (freezer)
- Temperature alarms– Visual and audible alarms alert if the interior temperature rises or falls out of set range
- Remote alarm contacts– Electronic controller is equipped with a volt-free contact for alarm forwarding to an external remote system (contacts located in the external rear of the unit)
- Automatic defrost with adjustable cycle defrost (refrigerator)– Adjustable cycle defrost operation ensures the unit avoid temperature spikes and ice buildup
- Manual defrost (freezer)– Static cooling system for reduced temperature fluctuations
- Access ports– Both units include a pre-installed probe hole to allow easier connection to user-provided monitoring equipment
- Open door alarms– Alarms will sound if the door is left ajar for over 4 minutes (adjustable from 1-99 minutes)
- Audible power failure alarms– Battery-powered alarms sound if the power connection is interrupted
- Sensor failure alarms– Audible and visual alarms warn if the sensor is disrupted
- Password protection– Control panels require password entry to adjust the parameters beyond the set point
- Microprocessor control panels– Digital controls with a large LED readout in Celsius or Fahrenheit for intuitive temperature management
- Resettable min/max displays– Control panels provide a readout of the low and high temperatures in 15 minute increments
- Factory-installed locks– Keyed lock conveniently located towards the top of the door for added security (2 keys included for each unit)
- Adjustable plastic-coated wire shelves for improved circulation– Designed to accommodate a variety of sizes for flexible storage
- Hospital grade cord with ‘green dot’ plug– Secure three-pronged cord for added unit safety
- Interior light– Energy efficient LED lighting with internal on/off switch
- Self-closing door– Added protection in busy settings; NOTE: door is not self-closing once reversed to an LHD swing
- Magnetic door gaskets– Quality door gaskets ensure a tight seal for energy savings and improved performance
- Extended warranty– 2 years parts and labor/5 years compressor
- Eco-Friendly (refrigerator)– Using environmentally friendly hydrocarbons refrigerants for a greener footprint
- Usage stickers– Ships with removable warning stickers for “DO NOT UNPLUG,” “DO NOT ADJUST TEMPERATURE,” and “DO NOT STORE PERSONAL ITEMS”
- Versatile design– Compatible with Pyxis®, Omnicell®, and AcuDose RX®
- 100% CFC free– Environmentally friendly design without ozone-damaging chemicals
- CARB Compliant– Eco-friendly hydrocarbon-based refrigerant for a greener footprint that meets current CARB regulations
Summit Medical Refrigerator Freezer Overview:
- Height of Cabinet– 72.25″
- Width– 23.38″
- Depth– 24.38″
- Capacity– 9.4 cu.ft.
- Door– White
- Cabinet– White
- US Electrical Safety– ETL
- Canadian Electrical Safety– ETL-C
- Voltage/Frequency– 115 V AC/60 Hz
- Parts & Labor Warranty– 2 Years
- Compressor Warranty– 5 Years
Summit Medical Refrigerator Freezer Features:
- Door Swing– RHD
- Reversible– Yes
- Adjustable Shelves– Yes
- Interior Light– Yes
- Refrigerator – Interior Height– 41.25″
- Refrigerator – Interior Width– 20.0″
- Refrigerator – Interior Depth– 17.0″
- Refrigerator – Capacity– 8.0 cu.ft
- Refrigerator – Shelf Type– Wire
- Refrigerator – Shelf Qty– 7
- Refrigerator – Temperature Range– 2 to 8ºC
- Refrigerator – Refrigerant Type– R600a
- Refrigerator – Refrigerant Amount– 1.73 oz.
- Freezer – Interior Height– 16.5″
- Freezer – Interior Width– 15.25″
- Freezer – Interior Depth– 15.75″
- Freezer – Capacity– 1.4 cu.ft
- Freezer – Shelf Type– Wire
- Freezer – Shelf Qty– 2
- Thermostat Type– Digital
- Fan Type– Interior
- Freezer – Temperature Range– -30 to -10ºC
- Freezer – Refrigerant Type– R290a
- Freezer – Refrigerant Amount– 0.85 oz.
Summit Appliance manufactures compact and specialty major appliances: including refrigerators, freezers, laboratory and scientific refrigeration and refrigerated and freezer drawers. Our products are grouped into: laboratory, medical and scientific refrigerators and freezers.
Product FAQ
What is the ARS8PV-AFZ1PVSTACK and what is it used for?
The ARS8PV-AFZ1PVSTACK is a 9.4 cu ft (~266 L) stacked medical storage unit combining an 8.0 cu ft (~227 L) +2 °C to +8 °C refrigerator section and a 1.4 cu ft (~39 L) -30 °C to -10 °C freezer section in a 59 cm wide footprint — designed for vaccine, pharmacy and clinical labs where both refrigerated and frozen zones are required together.
What are the key technical specifications?
• Capacity: 9.4 cu ft (~266 L) total (8.0 cu ft fridge + 1.4 cu ft freezer).
• External dimensions: Height ~184 cm, Width ~59 cm, Depth ~62 cm (~72.25″ H × 23.38″ W × 24.38″ D).
• Refrigerator section: +2 °C to +8 °C; 7 adjustable wire shelves.
• Freezer section: -30 °C to -10 °C; 2 adjustable wire shelves.
• Construction: White cabinet and doors; factory-installed keyed locks on both sections; hospital-grade cord.
• Monitoring/controls: Digital microprocessor controller, audible/visual alarms, remote alarm contacts, probe port included.
• Electrical (US model): 115 V AC / 60 Hz.
What safety and security features are included?
Features include:
– Audible/visual high/low temperature alarms for both fridge and freezer compartments.
– Remote alarm contacts for external building monitoring.
– Factory-installed keyed locks on each door.
– Self-closing door(s) (in fridge section default) and antimicrobial silver-ion-coated handles to help reduce germ spread.
Which environments is this unit best suited for?
Ideal for immunization clinics, hospital pharmacies, research labs or medical facilities that require both a reliable +2 °C to +8 °C refrigeration zone and a dedicated freezer zone (~-30 °C to -10 °C) in a space-saving 59 cm width cabinet. Not designed for ultra-low (≤ -80 °C) or large volume freezer operations without separate validation.
Shipping FAQ
How long does shipping take after placing an order?
Estimated shipping lead time: 1–2 business days when unit is in stock and ready for dispatch.
Is international shipping available and what should I consider for Melbourne, Australia?
Yes — international shipping is available. For delivery to Melbourne, Australia you should consider:
• Import duties, customs clearance and GST.
• Site access: Ensure corridors/doorways/elevators accommodate ~59 cm width × ~62 cm depth and allow sufficient front clearance for full door swing (approx 70–100 cm).
• Electrical compatibility: The US version is rated at 115 V AC / 60 Hz — for Australia (230 V / 50 Hz) you must order the export variant or install a certified step-down transformer by a licensed electrician.
How is the unit packaged for transit and what site requirements should be met?
The unit ships in three boxes (refrigerator, freezer and stacking rack) and is palletized. Unpacked footprint is approx. 184 cm H × 59 cm W × 62 cm D. The delivery path must be clear, level and firm.
What should I do if my shipment arrives damaged or delayed?
On arrival inspect the packaging and unit for visible damage. Photograph any signs of damage, retain the packaging and delivery receipt, and contact your supplier with the order/tracking details to initiate a freight claim or arrange replacement.
Application FAQ
How do I install and set up the ARS8PV-AFZ1PVSTACK?
1. Assemble the unit by installing the included “StackRack” base unit, place the fridge section on the bottom, then secure the freezer section on top per manufacturer instructions.
2. Place the assembled unit upright on a firm, level indoor surface in a climate-controlled room with clearance behind/top and sufficient front door-open clearance (~70–100 cm).
3. Connect to a dedicated grounded outlet matching the variant’s voltage and power supply.
4. Power the unit, set the refrigerator compartment to +2 °C to +8 °C and the freezer compartment to -30 °C to -10 °C, then allow 4–6 hours for temperature stabilization before loading sensitive contents.
What best practices should I follow when using this combined unit?
• Load the refrigerator shelves with proper spacing for airflow; avoid over-packing the compartment.
• Use the freezer section drawers/shelves similarly, ensuring items are not blocking airflow.
• Minimize door-open events for both compartments; rely on the digital display and alarm system for monitoring.
• Label contents with batch number and date/time, and apply first-in/first-out (FIFO) where relevant.
• Inspect door gasket/seal, hinge/lock function monthly, and ensure the unit remains level and clean.
What should I do if a temperature excursion or power interruption occurs?
If either compartment’s internal temperature rises above or falls below target range or power interruption occurs:
• Record date/time, observed temperature deviation and any impacted contents.
• Transfer critical items to validated backup storage until conditions stabilize.
• Investigate cause (door left ajar, ambient load spike, power/sensor fault).
• Once temperatures return to stable range, inspect contents for integrity before resuming normal use.
What maintenance and verification routines are recommended?
• Monthly: Check door gasket/seal, hinges/lock; verify unit remains level.
• Quarterly: Clean the interior and exterior surfaces, verify microprocessor control and any probe ports, review alarm operation.
• Periodically: Download or review logged high/low temperatures (if monitoring enabled), confirm calibration of probes/data loggers, maintain documented service/maintenance logs for compliance.