Description
Summit Vaccine Refrigerator Freezer Description:
Accucold offers innovative solutions to vaccine storage with stackable purpose-built refrigerator-freezer combinations designed to support meeting CDC/VFC guidelines.
Sized just under 24″ wide, the ARG6PV-VT65MLSTACKMED2 combines the 6 cu.ft. ARG6PV auto defrost all-refrigerator with VT65MLBIMED2 all-freezer into one slim footprint using Accucold’s StackRack. This ships in three boxes and requires some minor assembly upon delivery.
Summit ARG6PV-VT65MLSTACKMED2 Vaccine Refrigerator Freezer is part of Accucold’s Pharma-Vac Performance Series, designed to meet the demanding needs of vaccine storage. It utilizes a microprocessor temperature controller with an adjustable control range from +2 to +8ºC. The buffered temperature probe is encased in a glycol-filled bottle to better simulate temperature of the stored product, with an additional sensor that reads air temperature to ensure superior temperature control. The current and min/max temperature display is viewable in Celsius or Fahrenheit to the nearest tenth of a degree. The audible and visual temperature alarm sounds if the unit’s interior goes out of range. Additional alarms include a power failure alert, door open alarm, and sensor failure alarm. This unit is equipped with remote alarm contacts in the rear and a 1/2″ probe port on the right side to accept additional monitoring devices. The factory-installed antimicrobial handle is powder-coated with naturally occurring silver ions, which help to reduce the spread of germs, allowing for a safer, cleaner user experience. A hospital grade cord with ‘green dot’ plug is also included for added safety in high traffic areas.
Inside, the Summit ARG6PV-VT65MLSTACKMED2 Vaccine Refrigerator Freezer utilizes adjustable cycle defrost operation to avoid temperature spikes. Optimized forced air cooling with an internal fan ensures excellent temperature stability and uniformity with rapid recovery after door openings. The adjustable plastic-coated wire shelves can be positioned at 1/2″ increments to accommodate virtually any sized item. This unit includes LED internal lighting with an on/off rocker switch. The interior is constructed from white powder coated metal to ensure added durability and better temperature retention.
The refrigerator is designed to be stacked on top of the VT65MLBIMED2, a -25ºC all-freezer that utilizes manual defrost operation. The freezer includes three slide-out plastic storage drawers to better protect the contents from warmer ambient temperature when the door is opened. The digital control panel includes a NIST calibrated thermometer that provides a continuous display of the current and high/low temperature. This unit is also equipped with a temperature alarm and access port to accept additional monitoring equipment.
Both units include front-mounted keyed locks and powerful magnetic gaskets to ensure a positive seal. The refrigerator has a self-closing door for added protection in high traffic settings. Additional stacked combinations are available. Browse Accucold’s website for more information, or contact our sales team at 718-893-3900 to discuss your equipment needs.
NOTE: Accucold refrigerators are purpose-built to the support meeting the current CDC (Centers for Disease Control) guidelines for the storage of vaccines. At this time, Accucold refrigerators have not been evaluated to the new NSF 456 standard. As referenced in the current Vaccine Storage and Handling Toolkit, these units incorporate microprocessor controls and forced air circulation for stable operation between 2 and 8ºC. For additional temperature assurance, the CDC recommends a calibrated digital data logger (DDL), which can be added with the factory-installed option DL2B or addition of the DL2BKit accessory.
Summit Vaccine Refrigerator Freezer Features:
- Space-saving design– Allows you to create a full refrigerator-freezer with independent controls in a slim-fitting footprint
- Easy assembly– Unit ships in three boxes for customer to install the StackRack on the bottom refrigerator/freezer and place and secure the other unit on top
- Purpose-built design– Designed and purpose-built for pharmacy, medication, and vaccine applications to support meeting CDC/VFC guidelines
- +/-1ºC Variation (refrigerator)– The published temperature variation is derived from the maximum deviation of an NTC sensor in a 1 oz. vial located nearest the chamber geometric center during a 24 hour test period
- Adjustable temperature– Intuitive controls let you adjust the interior temperature between +2 to +8ºC (refrigerator) and -20º to -15ºC (freezer)
- Temperature alarms– Visual and audible alarms alert if the interior temperature rises or falls out of set range
- Remote alarm contacts (refrigerator)– Electronic controller is equipped with a volt-free contact for alarm forwarding to an external remote system (contacts located in the external rear of the unit)
- Automatic defrost with adjustable cycle defrost (refrigerator)– Adjustable cycle defrost operation ensures the unit avoid temperature spikes and ice buildup
- Manual defrost (freezer)– Static cooling system for reduced temperature fluctuations
- Access ports– Both units include a pre-installed probe hole to allow easier connection to user-provided monitoring equipment
- Open door alarm (refrigerator)– Alarm will sound if the door is left ajar for over 4 minutes (adjustable from 1-99 minutes)
- Audible power failure alarm (refrigerator)– Battery-powered alarm sounds if the power connection is interrupted
- Sensor failure alarm (refrigerator)– Audible and visual alarm warns if the sensor is disrupted
- Password protection (refrigerator)– Control panel requires password entry to adjust the parameters beyond the set point
- Microprocessor control panels– Digital controls with a large LED readout in Celsius or Fahrenheit for intuitive temperature management
- Resettable min/max display (refrigerator)– Control panel provides a readout of the low and high temperatures in 15 minute increments
- Factory-installed locks– Keyed lock conveniently located towards the top of the door for added security (2 keys included for each unit)
- Adjustable plastic-coated wire shelves for improved circulation– Designed to accommodate a variety of sizes for flexible storage
- Interior light (refrigerator)– Energy efficient LED lighting with internal on/off switch
- Self-closing door (refrigerator)– Added protection in busy settings; NOTE: door is not self-closing once reversed to an LHD swing
- Magnetic door gaskets– Quality door gaskets ensure a tight seal for energy savings and improved performance
- Extended warranty– 2 years parts and labor/5 years compressor
- Eco-Friendly (refrigerator)– Using environmentally friendly hydrocarbons refrigerants for a greener footprint
- Usage stickers– Ships with removable warning stickers for “DO NOT UNPLUG,” “DO NOT ADJUST TEMPERATURE,” and “DO NOT STORE PERSONAL ITEMS”
- Versatile design (refrigerator)– Compatible with Pyxis®, Omnicell®, and AcuDose RX®
- 100% CFC free– Environmentally friendly design without ozone-damaging chemicals
- CARB Compliant– Environmentally friendly hydrocarbon-based refrigerant for a greener footprint that meets current CARB regulations
Summit Vaccine Refrigerator Freezer Overview:
- Height of Cabinet– 68.0″
- Width– 23.63″
- Depth– 24.38″
- Depth with Handle– 26.13″
- Capacity– 9.2 cu.ft.
- Door– Glass
- Cabinet– White
- US Electrical Safety– ETL
- Canadian Electrical Safety– ETL-C
- Voltage/Frequency– 115 V AC/60 Hz
- Shipping Weight– 290.0 lbs.
- Parts & Labor Warranty– 2 Years
- Compressor Warranty– 5 Years
Summit Vaccine Refrigerator Freezer Features:
- Door Swing– RHD
- Reversible– Factory Reversible
- Adjustable Shelves– Yes
- Interior Light– Yes
- Refrigerator – Interior Height– 24.5″
- Refrigerator – Interior Width– 20.0″
- Refrigerator – Interior Depth– 17.0″
- Refrigerator – Capacity– 6.0 cu.ft
- Refrigerator – Shelf Type– Wire
- Refrigerator – Shelf Qty– 4
- Refrigerator – Temperature Range– 2 to 8ºC
- Refrigerator – Refrigerant Type– R600a
- Refrigerator – Refrigerant Amount– 1.66 oz.
- Freezer – Interior Height– 24.25″
- Freezer – Interior Width– 17.63″
- Freezer – Interior Depth–17.0″
- Freezer – Capacity– 3.2 cu.ft
- Thermostat Type– Digital
- Fan Type– Interior
- Freezer – Temperature Range– -12º to -25ºC
- Freezer – Refrigerant Type– R134a
- Freezer – Refrigerant Amount– 2.76 oz.
Summit Appliance manufactures compact and specialty major appliances: including refrigerators, freezers, laboratory and scientific refrigeration and refrigerated and freezer drawers. Our products are grouped into: laboratory, medical and scientific refrigerators and freezers.
Product FAQ
What is the ARG6PV-VT65MLSTACKMED2 and what is it used for?
The ARG6PV-VT65MLSTACKMED2 is a stacked combination unit purpose-built for pharmacy, medication and vaccine storage applications. It blends a ~6 cu ft (+2 °C to +8 °C) refrigerator section with a ~3.2 cu ft (-12 °C to -25 °C) freezer section in a slim 24-inch (~60 cm) wide footprint.
What are the key technical specifications?
• Combined capacity: 9.2 cu ft (~261 L).
• External dimensions: Approx. 173 cm H × 60 cm W × 62 cm D (Handle depth ~66 cm)
• Refrigerator section: 6.0 cu ft (~170 L); temperature range +2 °C to +8 °C.
• Freezer section: 3.2 cu ft (~90 L); temperature range approx. -12 °C to -25 °C.
• Voltage: 115 V AC / 60 Hz (US spec) — verify variant for Australia. Warranty: 2 yrs parts & labour; 5 yrs compressor.
What safety and monitoring features are included?
Includes: an antimicrobial silver-ion coated handle, factory installed keyed lock, remote alarm contacts, probe ports for external monitoring, visual & audible high/low temperature alarms, door open alarm, power failure alarm, password protected control (refrigerator section) and automatic defrost in fridge section.
Which environments is this unit best suited for?
Ideal for clinics, pharmacies, vaccine-storage rooms or medical settings requiring both refrigeration (+2 °C to +8 °C) and freezing (-12 °C to -25 °C) in a compact footprint. Not intended for ultra-low temperatures (-80 °C) unless specially validated.
What warranty coverage is provided?
Coverage: 2 years parts & labor; 5 years compressor parts.
Shipping FAQ
How long does shipping take after placing an order?
Typical lead time: about 5-7 days when in stock.
Is international shipping available and what should I consider for Melbourne, Australia?
Yes — international shipping is available. For delivery to Melbourne, Australia you should consider:
• Import duties, customs clearance & GST.
• Site access: Ensure width ~60 cm, depth ~62 cm plus door-open clearance (~118 cm) and height ~173 cm; verify floor loading, corridor, elevator access.
• Electrical compatibility: Unit is rated for 115 V AC/60 Hz (US version). For Australia’s 230 V/50 Hz supply, you must order the correct variant or use an approved transformer/adaptor.
How is the unit packaged for transit and what site requirements should be met?
Ships in three boxes (StackRack system). Unpacked footprint approx.: 173 cm H × 60 cm W × 62 cm D; allow extra clearance for door opening. Delivery site must have level, firm surface and clear access from vehicle to install location.
What should I do if my shipment arrives damaged or is delayed?
On delivery inspect packaging and unit for visible damage or transit issues. If damage is present: photograph condition, retain packaging and delivery receipt, then contact your supplier with order/tracking details for freight claim or replacement.
Application FAQ
How do I install and set up the ARG6PV-VT65MLSTACKMED2?
1. Position the unit in its final location on a firm, level indoor surface. Ensure adequate clearance behind and above for ventilation and front clearance for full door swing (~118 cm).
2. Assemble per manufacturer instructions: install bottom refrigerator section, stack and secure freezer section using the StackRack bracket (ships in three boxes).
3. Connect the unit to a dedicated grounded outlet matching local voltage and frequency (US version: 115 V/60 Hz). For Australia ensure the correct variant or suitable transformer is installed.
4. Power on, set refrigerator section to target +2 °C to +8 °C and freezer to target -12 °C to -25 °C, then allow 4-6 hours for temperature stabilization before loading vaccines or sensitive items.
What best practices should I follow when using this refrigerator/freezer combination?
• Use the adjustable wire shelves (refrigerator) and slide-out drawers (freezer) with proper spacing to allow airflow; avoid over-packing which may impair temperature uniformity.
• Label stored items with date/time/batch number and employ a first-in/first-out (FIFO) system where applicable.
• Minimize door-open time; rely on external display, alarms or digital logger to monitor temperature instead of frequent checks.
• Regularly inspect seals/gasket, door self-close (refrigerator section), lock/handle mechanism, and keep the interior clean and level.
What should I do if a temperature excursion or power interruption occurs?
If internal temperature moves outside the target range or a power interruption occurs:
• Record event: date/time, recorded temperature, affected contents.
• Move critical items to validated backup storage until conditions stabilize.
• Investigate root cause (e.g., door left open too long, ambient heat load, power/sensor fault).
• Once stable and within range, verify stored contents before returning to routine use.
What maintenance and verification routines are recommended?
• Monthly: Check door gasket/seal, self-closing mechanism, hinges, lock/handle and ensure unit remains level.
• Quarterly: Clean external surfaces and interior, inspect ventilation inlets/outlets, check alarm and probe port function.
• Periodically: Maintain logs of minimum/maximum internal temperatures using the included digital controller or external logger, keep calibration certificates current, and maintain service/maintenance records—critical for regulated vaccine-storage environments.