Description
Summit Compact Vaccine Pharmacy Refrigerator Description:
Accucold’s Pharma-Vac Performance Series are upright all-refrigerators designed and purpose-built for pharmacy, medication, and vaccine applications to support meeting CDC/VFC guidelines, with a powder-coated silver ion handle that helps prevent germ spread.
The Summit ARS1PVDL2B Compact Vaccine Pharmacy Refrigerator is a 1 cu.ft. all-refrigerator with an adjustable control range from +2 to +8ºC. The microprocessor temperature controller is externally located to minimize door openings, helping to protect stored contents from ambient temperature. The buffered temperature probe is encased in a glycol-filled bottle to better simulate temperature of the stored product, with an additional sensor that reads air temperature to ensure superior temperature control. The current and min/max temperature display is viewable in Celsius or Fahrenheit to the nearest tenth of a degree. This refrigerator includes a high/low temperature alarm, as well as a power failure alert, door open alarm, and sensor failure alarm. This unit is equipped with remote alarm contacts in the rear and a 1/2″ probe port, as well as a hospital grade cord with ‘green dot’ plug for added safety in high traffic areas.
We also include our DL2B digital data logger to be mounted to the door, a feature recommended by the CDC and VFC for vaccine storage. This password-protected DDL is NIST calibrated in our ISO/IEC 17025:2017 accredited laboratory and offers a large LCD display of the current and high/low temperature, recording up to 32,000 data groups to its internal memory or even more on the included 4GB USB flash drive. Data can be viewed through a PC or Mac in Microsoft Excel or any .CSV compatible program. Users can set their own recording intervals starting at increments of 10 seconds to best meet a facility’s specific logging needs. We include a 2-year certificate of calibration beginning the date of manufacture. The logger can be re-calibrated in our laboratories after the certificate expires. (For additional information on the DDL, see the DL2BKit listing on our website.)
Inside, the Summit ARS1PVDL2B Compact Vaccine Pharmacy Refrigerator utilizes adjustable cycle defrost operation to avoid temperature spikes. Optimized forced air cooling with an internal fan to ensures excellent temperature stability and uniformity with rapid recovery after door openings. The adjustable plastic-coated wire shelves can be positioned at 1/2″ increments to accommodate virtually any sized item. This unit includes LED internal lighting with an on/off rocker switch. The interior is constructed from white powder coated metal to ensure added durability and better temperature retention.
The Summit ARS1PVDL2B Compact Vaccine Pharmacy Refrigerator comes in a white cabinet finish with a blue accented control panel. The factory-installed antimicrobial handle is powder-coated with naturally occurring silver ions, which help to reduce the spread of germs, allowing for a safer, cleaner user experience. This model includes a factory-installed lock and ships with two keys for staff use. Powerful magnetic gaskets ensure a positive seal.
Designed with hydrocarbon refrigerant, the ARS1PVDL2B provides an energy efficient solution to vaccine storage. This unit is Pyxis, Omnicell, and AcuDose RX compatible. Additional sizes, as well as solid door options, are also available. Explore the full Pharma-Vac series at accucold.com/pharmavac.
Note: The DL2B data logger adds 1 1/2″ to the depth of the upper right hand corner of the door (not included in the listed specifications on this page).
NOTE: Accucold refrigerators are purpose-built to the support meeting the current CDC (Centers for Disease Control) guidelines for the storage of vaccines. At this time, Accucold refrigerators have not been evaluated to the new NSF 456 standard. As referenced in the current Vaccine Storage and Handling Toolkit, these units incorporate microprocessor controls and forced air circulation for stable operation between 2 and 8ºC, as well as a calibrated digital data logger (DDL) to display the current and high/low temperature.
Summit Compact Vaccine Pharmacy Refrigerator Features:
- Purpose-built design– Designed and purpose-built for pharmacy, medication, and vaccine applications to support meeting CDC/VFC guidelines
- +/-1ºC Variation– The published temperature variation is derived from the maximum deviation of an NTC sensor in a 1 oz. vial located nearest the chamber geometric center during a 24 hour test period
- Adjustable temperature– Intuitive controls let you adjust the interior temperature between +2 to +8ºC
- Temperature alarm– Visual and audible alarms alert if the interior temperature rises or falls out of set range
- Digital data logger (DDL) included– Accucold DL2B data logger is NIST calibrated in our ISO/IEC 17025:2017 laboratory, with user-set logging intervals, a large LCD readout of the current and high/low temperature, and virtually unlimited storage through internal memory and a convenient USB drive
- Temperature alarm– Visual and audible alarms alert if the interior temperature rises or falls out of set range
- Remote alarm contacts– Electronic controller is equipped with a volt-free contact for alarm forwarding to an external remote system (contacts located in the external rear of the unit)
- Automatic defrost with adjustable cycle defrost– Adjustable cycle defrost operation ensures the unit avoid temperature spikes and ice buildup
- Access port– Includes a pre-installed 1/2″ probe hole in the right interior wall to allow easier connection to user-provided monitoring equipment
- Open door alarm– Alarm will sound if the door is left ajar for over 4 minutes (adjustable from 1-99 minutes)
- Audible power failure alarm– Battery-powered alarm sounds if the power connection is interrupted
- Sensor failure alarm– Audible and visual alarm warns if the sensor is disrupted
- Password protection– Control panel requires password entry to adjust the parameters beyond the set point
- Microprocessor control panel– Digital controls with a large LED readout in Celsius or Fahrenheit for intuitive temperature management
- Resettable min/max display– Control panel provides a readout of the low and high temperatures in 15 minute increments
- Factory-installed lock– Keyed lock conveniently located towards the top of the door for added security (2 keys included)
- Adjustable plastic– coated wire shelves for improved circulation– Multiple shelf positions spaced at 1/2″ to accommodate virtually any size
- Durable interior– Walls are constructed from white powder coated metal for added strength and improved temperature retention
- Interior light– Energy efficient LED lighting with internal on/off switch
- Hospital grade cord with ‘green dot’ plug– Secure three-pronged cord for added unit safety
- Self-closing door– Added protection in busy settings; NOTE: door is not self-closing once reversed to an LHD swing
- Magnetic door gasket– Quality door gaskets ensure a tight seal for energy savings and improved performance
- Extended warranty– 2 years parts and labor/5 years compressor
- Eco-Friendly– Using environmentally friendly hydrocarbons refrigerants for a greener footprint
- Usage stickers– Ships with removable warning stickers for “DO NOT UNPLUG,” “DO NOT ADJUST TEMPERATURE,” and “DO NOT STORE PERSONAL ITEMS”
- Additional choices– Solid and glass door choices available from 1 to 15 cu.ft.
- Versatile design– Compatible with Pyxis®, Omnicell®, and AcuDose RX®
- 100% CFC free– Environmentally friendly design without ozone-damaging chemicals
- CARB Compliant– Environmentally friendly hydrocarbon-based refrigerant for a greener footprint that meets current CARB regulations
Summit Compact Vaccine Pharmacy Refrigerator Overview:
- Height of Cabinet– 21.5″
- Width– 17.5″
- Width with Door Open– 18.0″
- Depth– 19.75″
- Depth with Handle– 21.5″
- Depth with door at 90°– 36.0″
- Capacity– 1.0 cu.ft.
- Defrost Type– Automatic
- Door– White
- Cabinet– White
- US Electrical Safety– ETL
- Canadian Electrical Safety– ETL-C
- Amps– 0.6
- Voltage/Frequency– 115 V AC/60 Hz
- Weight– 63.0 lbs.
- Shipping Weight– 97.0 lbs.
- Parts & Labor Warranty– 2 Years
- Compressor Warranty– 5 Years
Summit Compact Vaccine Pharmacy Refrigerator Features:
- Door Swing– RHD
- Reversible– Factory Reversible
- Shelf Type– Wire
- Shelf Qty– 3
- Adjustable Shelves– Yes
- Thermostat Type– Digital
- Fan Type– Interior
- Refrigerant Type– R600a
- Refrigerant Amount– .71oz.
- Interior Light– Yes
- Temperature Range– 2 to 8ºC
Summit Appliance manufactures compact and specialty major appliances: including refrigerators, freezers, laboratory and scientific refrigeration and refrigerated and freezer drawers. Our products are grouped into: laboratory, medical and scientific refrigerators and freezers.
Product FAQ
What is the ARS1PVDL2B and what is it used for?
The ARS1PVDL2B is a 1 cu ft (~28 L) compact upright refrigerator purpose-built for vaccine, medication and pharmacy-grade storage applications. It supports a temperature control range of +2 °C to +8 °C, includes microprocessor control, NIST-calibrated data logger and antimicrobial silver-ion handle.
What are the key technical specifications?
• Capacity: 1.0 cu ft (~28 L)
• Exterior dimensions: ~55 cm H × ~44 cm W × ~50 cm D (21.5″ H × 17.5″ W × 19.75″ D)
• Temperature range: +2 °C to +8 °C
• Defrost type: Automatic cycle defrost
• Alarm/monitoring & extras: Includes visual/audible high/low-temp alarms, power failure alarm, door-open alarm, sensor failure alarm, remote alarm contacts, factory lock and antimicrobial handle.
• Electrical: 115 V AC/60 Hz (U.S. spec) ~0.6 Amps; weight approx. ~29 kg (63 lbs)
Which environments is this unit best suited for?
Ideal for risk-controlled environments such as clinics, pharmacies, immunization stations or lab spaces requiring compact, secure +2 °C to +8 °C refrigeration for vaccines or medications. Not designed for ultra-low (e.g., -20 °C or lower) sample storage without further validation.
What warranty coverage is provided?
The unit comes with a 2-year parts & labor warranty and a 5-year compressor parts warranty.
Shipping FAQ
How long does shipping take after placing an order?
When in stock, lead time for dispatch is generally 3–5 business days (manufacturer dependent).
Is international shipping available and what should I consider for Melbourne, Australia?
Yes — international shipping is possible. For delivery to Melbourne, Australia consider:
• Import duties, customs clearance & GST.
• Site access: verify doorway/corridor width and elevator clearance for unit approx. 44 cm wide × 50 cm deep; allow depth clearance for door open (~91 cm) as listed.
• Electrical compatibility: This model is rated at 115 V AC/60 Hz (U.S. spec). For Australia (230 V/50 Hz) verify you order a compatible variant or arrange suitable transformer/adapter.
How is the unit packaged for transit and what site requirements should be met?
The unit ships boxed or palletized; unpacked footprint ~55 cm H × 44 cm W × 50 cm D; allow approx. 91 cm depth for door swing. Delivery area should be level, firm, and clear of obstacles for installation.
What should I do if my shipment arrives damaged or is delayed?
On delivery inspect packaging and unit for visible damage or signs of transit delay. If damage is found, photograph the condition, retain all packaging and the delivery receipt, then contact your supplier with tracking/order details to initiate a freight claim or replacement.
Application FAQ
How do I install and set up the ARS1PVDL2B?
1. Place the unit upright on a firm, level indoor surface in a climate-controlled space; allow sufficient clearance behind and above for ventilation and ensure door swing depth (~91 cm) is unobstructed.
2. Connect to a dedicated grounded outlet compatible with the unit (115 V AC/60 Hz U.S. spec or correct variant for Australia) and switch on power.
3. Using the digital microprocessor control panel, set the interior temperature to the target range (+2 °C to +8 °C) and allow at least 2–4 hours for the interior to stabilize before loading sensitive medical materials.
4. Verify door locking mechanism, digital data logger (included), alarm functions (high/low temp, door open, power failure), and shelf installation are correct.
What best practices should I follow when using this compact vaccine refrigerator?
• Store items in original packaging, label with date/time and rotate inventory (first-in/first-out) if relevant.
• Avoid over-packing the interior; allow airflow around stored items and ensure shelves are correctly positioned for uniform cooling.
• Minimize door-opening frequency and duration; use the external display/logger to monitor temperature without opening the door if possible.
• Regularly inspect the door gasket/seal, ensure the antimicrobial handle and lock work properly, and clean the interior periodically.
What should I do if a temperature excursion or power interruption occurs?
If internal temperature moves outside the target +2 °C to +8 °C range or power interruption occurs:
• Record the event: date/time, observed temperature, contents impacted.
• Move critical items to validated backup storage if needed until the unit recovers.
• Investigate root cause (for example: door left open, ambient heat load, sensor or power fault).
• Once temperature is within the correct range and stable, inspect stored items before returning to routine use.
What maintenance and verification routines are recommended?
• Monthly: Check door gasket, seal integrity, lock and handle operation, and ensure the unit remains level.
• Quarterly: Clean external surfaces and interior, check ventilation and fan function, verify alarms and data logger operation.
• Periodically: Review the minimum and maximum internal temperature logs, ensure calibration certificate for the data logger is current and maintain service records — especially important for clinical or regulated vaccine-storage applications.