Description
Summit Undercounter General Purpose Medical Freezer Description:
Accucold’s PRO Series features all-refrigerators and all-freezers designed for reliable temperature stability in institutional settings.
Sized at 32″ high and just under 24″ wide, the Summit VT65MLPROADA Undercounter General Purpose Medical Freezer is an all-freezer designed for freestanding use in hospitals, doctors’ offices, and other facilities with specific temperature needs following ADA guidelines for lower counter height. Made in Europe, it comes in a white finish with a fully finished cabinet. A hospital grade cord with a ‘green dot’ plug offers added safety in high traffic areas and factory-installed lock is located towards the top of the unit for convenient security. A digital thermostat is located in the kickplate for easy temperature management.
This manual defrost -25ºC capable unit features three removable interior drawers with clear fronts, ideal for keeping contents protected from ambient temperature when the door is opened. It has a flat door liner as recommended by the CDC and VFC. An access port is installed in the rear to allow users to install their own temperature monitoring equipment.
The VT65MLPROADA can be paired with a matching all-refrigerator (model FF6LPROADA or FF7LPROADA). Additional options, including NIST calibrated temperature alarms and data loggers, can also be added. Contact our product specialists for more information.
Summit Undercounter General Purpose Medical Freezer Features:
- ADA compliant– 32″ height for use in ADA compliant settings
- Factory installed lock– Top-mounted keyed lock for convenient security
- Access port– Pre-installed 3/8″ probe hole included in the rear allows users to connect their own monitoring equipment
- -25ºC capable– Low temperature capability ideal for certain sensitive items
- Manual defrost– Efficient performance with reliable temperature stability
- Pull-out drawers– -Clear baskets for convenient and separated storage
- Digital thermostat– Electronic controls located in the front kickplate for easy and intuitive temperature management
- Magnetic door gasket– Quality door gaskets ensure a tight seal for energy savings and improved performance
- Foamed-in-place cabinet– Designed to ensure a sufficiently insulated interior
- Matching refrigerator available– Pair with FF6LPROADA for a complete ADA compliant set
- Approved for use in the USA and Canada– ETL and ETL-C listed for North American sales
- Fully finished white cabinet– Allows the unit to be used freestanding
- Factory reversible door– Standard unit ships with a right hand door swing. For a left hand door swing, add option LHD upon order (due to its construction, this door is not reversible in the field)
- 100% CFC Free– Environmentally friendly design without ozone-damaging chemicals
Summit Undercounter General Purpose Medical Freezer Specifications:
- Height of Cabinet– 32.0″
- Height to Hinge Cap– 32.25″
- Width– 23.63″
- Depth– 23.5″
- Depth with Handle– 24.25″
- Depth with door at 90°– 45.0″
- Capacity– 3.2 cu.ft.
- Defrost Type– Manual
- Door– White
- Cabinet– White
- US Electrical Safety– ETL
- Canadian Electrical Safety– ETL-C
- Amps– 1.3
- Voltage/Frequency– 115 V AC/60 Hz
- Shipping Weight– 105.0 lbs.
- Shipping Weight– 110.0 lbs.
- Parts & Labor Warranty– 1 Year
- Compressor Warranty– 5 Years
Summit Undercounter General Purpose Medical Freezer Features:
- Door Swing– RHD
- Reversible– Factory Reversible
- Interior Height– 24.25″
- Interior Width– 17.75″
- Interior Depth– 16.5″
- Thermostat Type– Digital
- Refrigerant Type– R134a
- Refrigerant Amount– 2.7 oz.
- High Side PSI– 235.0
- Low Side PSI– 70.0
- Interior Drawers– Yes
- Drawers Qty– 3
- Compressor Step Height– 6.5″
- Compressor Step Width– 17.5″
- Compressor Step Depth– 5.5″
- Temperature Range– -12ºC to -25ºC
Summit Appliance manufactures compact and specialty major appliances: including refrigerators, freezers, laboratory and scientific refrigeration and refrigerated and freezer drawers. Our products are grouped into: laboratory, medical and scientific refrigerators and freezers.
Product FAQ
What is the VT65MLPROADA and what is it used for?
The VT65MLPROADA is a 3.2 cu ft (~91 L) upright all-freezer, ADA-compliant height (32″/81 cm), built for medical or laboratory settings where compact, reliable freezer storage down to -25 °C is required.
What are the key technical specifications?
• Capacity: 3.2 cu ft (~91 L).
• External dimensions: Height ~81 cm (32″), Width ~60 cm (23.63″), Depth ~60 cm (23.5″); door-open depth ~114 cm (45″).
• Temperature range: approx. -12 °C to -25 °C.
• Defrost type: Manual.
• Door: Solid white finish with factory-installed keyed lock; top-mounted lock.
• Monitoring: Pre-installed 3/8″ probe hole for user-provided monitoring equipment.
• Power: 115 V AC / 60 Hz, 1.3 amps.
• Warranty: 1 year parts & labor; 5 years compressor.
What safety and security features are included?
Features include:
– Factory-installed keyed lock for secure access.
– Access port for external monitoring probe for regulated storage oversight.
– Flat door liner, magnetic gasket and foamed-in-place insulation to support temperature stability.
Which environments is this unit best suited for?
Ideal for healthcare clinics, laboratories, pharmacy ancillary storage or any facility requiring compact, low-temperature freezer capacity under 25 °C in an ADA-accessible height. Not designed for vaccines unless specifically validated or for ultra-low (≤ -80 °C) storage.
Shipping FAQ
How long does shipping take after placing an order?
Estimated lead time is about 3–5 business days once the unit is in stock and ready for dispatch.
Is international shipping available and what should I consider for Melbourne, Australia?
Yes — international shipping is available. For delivery to Melbourne, Australia you should consider:
• Import duties, customs clearance and GST.
• Site access: ensure corridors/lifts can accommodate ~60 cm width × ~60 cm depth and ~81 cm height, and allow ~114 cm front clearance for full door opening.
• Electrical compatibility: unit rated at 115 V AC / 60 Hz (U.S. version) — for Australian 230 V / 50 Hz you must order correct export variant or install certified step-down transformer by a licensed electrician.
How is the unit packaged for transit and what site requirements should be met?
The unit ships palletized/boxed; unpacked footprint ~81 cm H × ~60 cm W × ~60 cm D; door-open depth ~114 cm. Ensure delivery path is level, firm and clear from vehicle to installation point.
What should I do if my shipment arrives damaged or delayed?
Upon delivery inspect the outer packaging and unit for visible damage. Photograph any damage, retain the packaging and delivery receipt, and contact your supplier with your order/tracking details to initiate a freight claim or arrange replacement.
Application FAQ
How do I install and set up the VT65MLPROADA?
1. Place the unit upright on a firm, level indoor surface in a climate-controlled environment; allow clearance behind/above and approximately ~114 cm front clearance for full door opening.
2. Connect to a dedicated grounded outlet matching the unit’s voltage.
3. Power on the unit, set the digital thermostat, and allow several hours (typically 2–4 h) for the temperature to stabilize before loading sensitive materials.
What best practices should I follow when using this freezer?
• Use the clear basket drawers and ensure items are spaced for airflow; avoid over-packing the interior which can affect recovery performance.
• Label stored items (batch number, date/time) and apply first-in/first-out (FIFO) rotation if applicable.
• Minimize door-open duration; rely on external monitoring where possible.
• Regularly inspect door gasket/seal, hinges and lock; keep the unit level and clean interior surfaces.
What should I do if a temperature excursion or power interruption occurs?
If internal temperature falls below or rises above target (-12 °C to -25 °C) or a power interruption occurs:
• Record the event: date/time, observed temperature, and impacted contents.
• Transfer critical materials to validated backup storage until conditions stabilize.
• Investigate root cause (door left open, ambient heat load, power/sensor fault).
• Once temperatures return to stable target range, inspect contents for integrity before resuming routine use.
What maintenance and verification routines are recommended?
• Monthly: Check door gasket/seal, hinges and lock; ensure unit remains level.
• Quarterly: Clean interior/exterior surfaces; verify drawers slide freely, inspect insulation, check the manual defrost path, test monitoring port/thermostat function.
• Periodically: Download or record temperature logs (if supported), verify calibration certificates and keep documented service/maintenance records for compliance.